What's in It
Facility and Inspection Record
- WDID
- SIC code
- Receiving water
- Inspector certification
- Current ERA level
The header fields an auditor looks for first.
Weather and Discharge
- Rainfall
- Storm start
- Whether the event qualified
The qualifying storm event definition is printed on the page so you're not guessing in the rain.
Discharge Location Observations
A row per outfall for the five things you're required to look for, logged where you looked:
- Floating and suspended material
- Sheen
- Discoloration
- Turbidity
- Odor
Industrial Activity Areas
Twelve areas worth walking, including the ones that quietly generate metals:
- Galvanized roofing and downspouts
- Parking and traffic surfaces
- Uncovered material storage
- Scrap and waste handling
Minimum BMPs
The seven required at every permitted facility, in a form somebody else can read.
Treatment Control BMPs
A row per unit that makes you write down when the media went in.
Benchmark Quick Reference
Zinc, copper, pH, TSS, and oil and grease — on one page, across:
- California IGP
- Washington ISGP
- Oregon 1200-Z
- EPA MSGP
We couldn't find that published anywhere, so we built it.
Corrective Actions and Certification
- Findings
- Owners
- Due dates
- Signature
- Retention requirement
Ready to Walk Your Site?
All eight sections on four fillable pages. No email, no gate — take it with you on your next inspection.
download the checklistBenchmark Quick Reference
This table matches page 3 of the Gullywasher Industrial Stormwater Inspection Checklist — download it and the benchmarks ride along on every inspection, next to the fields where you log your results.
| Parameter | CA IGP (annual NAL) | WA ISGP | OR 1200-Z | EPA MSGP |
|---|---|---|---|---|
| Total zinc | 0.26 mg/L | 0.117 mg/L | 0.120 mg/L | Hardness-dependent |
| Total copper | 0.0332 mg/L | 0.014 mg/L | 0.020 mg/L | Hardness-dependent |
| pH | 6.0 – 9.0 | 5.0 – 9.0 | 5.5 – 9.0 | 6.0 – 9.0 |
| Total suspended solids | 100 mg/L | — | 100 mg/L | 100 mg/L |
| Oil & grease | 15 mg/L | 10 mg/L | 10 mg/L | 15 mg/L |
A TMDL on your receiving water can set limits well below these. EPA MSGP zinc and copper are hardness-dependent — zinc typically falls between 0.037 and 0.260 mg/L. Verify against your own permit and receiving water before you rely on any number here.